Price: Call
4 Gas analyzer CO, CO², HC, O² Capelec CAP3201-G
The CAP3201, is an accurate exhaust 4 gas analyzer that compares and measures emission levels against limits specified by governmental Roadworthiness, PTI (on cars, trucks, vans,
camping car, ...)
- Gazoline, GLP (optional)
- LCD screen
- QWERTY keyboard
- Built in thermal report printer
- Inductive RPM
- 6mm piezo RPM
- Oil temperature probe
- Mobile workshop trolley
- Safe data (optional) : GIEG NET / GIEG LAN
- Made in France
Gaz analyzer | Gazoline, GLP
- Complying with standard : OIML R99 Classe 0, ISO 3930 and BAR97
- Dual mode : diagnostic and vehicle inspection
- Measuring the concentrations of : Hydrocarbons (HC), Carbon monoxide (CO), and Carbon dioxide (CO2)
- Gazoline engine
- Treatment of O2 Sensor input
- Treatment of Nox Sensor input
- Warm-up time :< 9 minutes at 0°C (1 minute minimum ) for full performance
- Response time : < 5 seconds for Co, Co2, HC
- Operating temperature : -10°C to 55 °C
- Storage temperature : -20°C to 70°C
- Humidity : 0 to 95 % relative
- Ambient pressure : 750 mBar to 1150 mBar
- Measurement
HC
- Normal resolution : 0 to 2000ppm
- High resolution: Propane 2001 to 20000ppm Propane
CO 0 to 5%
CO2 0 to 20%
O2 0 to 25%
Nox 0 to 5000 ppm
Engine speed 0 to 9999 rpm
Oil temperature 0 to 150°C
Corrected CO 0 to 10%
Air/fuel coefficient (Lambda) 0 to 9,99
Stamping the standards of the Vietnam Registry Department
The CAP3201, is an accurate exhaust 4 gas analyzer that compares and measures emission levels against limits specified by governmental Roadworthiness, PTI (on cars, trucks, vans,
camping car, ...)
- Gazoline, GLP (optional)
- LCD screen
- QWERTY keyboard
- Built in thermal report printer
- Inductive RPM
- 6mm piezo RPM
- Oil temperature probe
- Mobile workshop trolley
- Safe data (optional) : GIEG NET / GIEG LAN
- Made in France
Gaz analyzer | Gazoline, GLP
- Complying with standard : OIML R99 Classe 0, ISO 3930 and BAR97
- Dual mode : diagnostic and vehicle inspection
- Measuring the concentrations of : Hydrocarbons (HC), Carbon monoxide (CO), and Carbon dioxide (CO2)
- Gazoline engine
- Treatment of O2 Sensor input
- Treatment of Nox Sensor input
- Warm-up time :< 9 minutes at 0°C (1 minute minimum ) for full performance
- Response time : < 5 seconds for Co, Co2, HC
- Operating temperature : -10°C to 55 °C
- Storage temperature : -20°C to 70°C
- Humidity : 0 to 95 % relative
- Ambient pressure : 750 mBar to 1150 mBar
- Measurement
HC
- Normal resolution : 0 to 2000ppm
- High resolution: Propane 2001 to 20000ppm Propane
CO 0 to 5%
CO2 0 to 20%
O2 0 to 25%
Nox 0 to 5000 ppm
Engine speed 0 to 9999 rpm
Oil temperature 0 to 150°C
Corrected CO 0 to 10%
Air/fuel coefficient (Lambda) 0 to 9,99
Stamping the standards of the Vietnam Registry Department
Others